      <ArticleType>Mechatronics Engineering</ArticleType>
      <ArticleTitle>Experimental Evaluation of Hall Sensor Placement for Gap Sensing in a Magnetic Levitation Setup</ArticleTitle>
      <SubTitle/>
      <ArticleLanguage>English</ArticleLanguage>
      <ArticleOA>Y</ArticleOA>
      <FirstPage>38</FirstPage>
      <LastPage>47</LastPage>
      <AuthorList>
        <Author>
          <FirstName>Okan Uyar</FirstName>          
          <AuthorLanguage>English</AuthorLanguage>
          <Affiliation/>
          <CorrespondingAuthor>Y</CorrespondingAuthor>
          <ORCID/>
             
        </Author>
      </AuthorList>
      <DOI>https://doi.org/10.55524/ijircst.2026.14.6.5</DOI>
      <Abstract>Hall-effect sensors can measure the air gap in magnetic levitation inexpensively, but the electromagnet field is superimposed on that of the levitated magnet. This study compares two sensor locations on a pot-type electromagnet levitating an NdFeB magnet: a linear Hall sensor on the pole face (S1) and a second sensor close to the back face (S2). The outputs were recorded at 11 gaps between 11 and 30 mm, for coil currents between 0 and 0.25 A and lateral positions of up to &amp;plusmn;4 mm (214 readings). A separate lift-off test placed the estimated levitation window between 14.4 and 26.6 mm. S1 was about 21 times more gap-sensitive than S2 (20.5 versus 0.95 mV/mm at 21 mm), but its coil contribution at the rated current equalled an apparent gap change of about 30 mm. For S1 this contribution was nearly linear, gap-independent and almost unchanged by the magnet. A current coefficient identified on the increasing branch of a sweep left an equivalent current residual of 0.26 mm on the decreasing branch of the same sweep (window median; 0.96 mm at 21 mm); a single coefficient from other gaps or from the coil-only test left about 1.8 mm on the same readings. The dual-sensor difference performed worse (6.1 mm) because the coil-cancelling ratio exceeded the magnet sensitivity ratio. For the accepted lateral profiles, &amp;plusmn;2 mm changed the S1 reading by the equivalent of 0.3&amp;ndash;1.0 mm. A centred pole-face sensor with a current coefficient identified near the operating gap is recommended.</Abstract>
      <AbstractLanguage>English</AbstractLanguage>
      <Keywords>Current Compensation, Gap Sensing, Hall-Effect Sensor, Magnetic Levitation, Sensor Placement</Keywords>